Arrhythmia management after device removal

Abstract Arrhythmic management is needed after removal of cardiac implantable electronic devices (CIEDs). Patients completely dependent on CIEDs need temporary device back-up until new CIEDs are implanted. Various methods are available for device back-up, and the appropriate management varies among...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of arrhythmia 2016-08, Vol.32 (4), p.287-292
1. Verfasser: Nishii, Nobuhiro, MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Arrhythmic management is needed after removal of cardiac implantable electronic devices (CIEDs). Patients completely dependent on CIEDs need temporary device back-up until new CIEDs are implanted. Various methods are available for device back-up, and the appropriate management varies among patients. The duration from CIED removal to implantation of a new CIED also differs among patients. Temporary pacing is needed for patients with bradycardia, a wearable cardioverter defibrillator (WCD) or catheter ablation is needed for patients with tachyarrhythmia, and sequential pacing is needed for patients dependent on cardiac resynchronization therapy. The present review focuses on arrhythmic management after CIED removal.
ISSN:1880-4276
1883-2148
DOI:10.1016/j.joa.2015.09.004