Salivary Electrochemical Cortisol Biosensor Based on Tin Disulfide Nanoflakes

Cortisol, a steroid hormone, is secreted by the hypothalamic-pituitary-adrenal system. It is a well-known biomarker of psychological stress and is hence known as the “stress hormone.” If cortisol overexpression is prolonged and repeated, dysfunction in the regulation of cortisol eventually occurs. T...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nanoscale research letters 2019-06, Vol.14 (1), p.189-9, Article 189
Hauptverfasser: Liu, Xinke, Hsu, Sanford P. C., Liu, Wai-Ching, Wang, Yi-Min, Liu, Xinrui, Lo, Ching-Shu, Lin, Yu-Chien, Nabilla, Sasza Chyntara, Li, Zhiwen, Hong, Yuehua, Lin, Chingpo, Li, Yunqian, Zhao, Gang, Chung, Ren-Jei
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Cortisol, a steroid hormone, is secreted by the hypothalamic-pituitary-adrenal system. It is a well-known biomarker of psychological stress and is hence known as the “stress hormone.” If cortisol overexpression is prolonged and repeated, dysfunction in the regulation of cortisol eventually occurs. Therefore, a rapid point-of-care assay to detect cortisol is needed. Salivary cortisol electrochemical analysis is a non-invasive method that is potentially useful in enabling rapid measurement of cortisol levels. In this study, multilayer films containing two-dimensional tin disulfide nanoflakes, cortisol antibody (C-M ab ), and bovine serum albumin (BSA) were prepared on glassy carbon electrodes (GCE) as BSA/C-M ab /SnS 2 /GCE, and characterized using electrochemical impedance spectroscopy and cyclic voltammetry. Electrochemical responses of the biosensor as a function of cortisol concentrations were determined using cyclic voltammetry and differential pulse voltammetry. This cortisol biosensor exhibited a detection range from 100 pM to 100 μM, a detection limit of 100 pM, and a sensitivity of 0.0103 mA/Mcm 2 ( R 2 = 0.9979). Finally, cortisol concentrations in authentic saliva samples obtained using the developed electrochemical system correlated well with results obtained using enzyme-linked immunosorbent assays. This biosensor was successfully prepared and used for the electrochemical detection of salivary cortisol over physiological ranges, based on the specificity of antibody-antigen interactions.
ISSN:1931-7573
1556-276X
DOI:10.1186/s11671-019-3012-0