Lung contusion and cavitation with exudative plural effusion following extracorporeal shock wave lithotripsy in an adult: a case report

Among the complications of extracorporeal shock wave lithotripsy are perinephric bleeding and hypertension. We describe the case of a 31-year-old Asian man with an unusual case of hemoptysis and lung contusion and cavitation with exudative plural effusion due to pulmonary trauma following false posi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of medical case reports 2010-08, Vol.4 (1), p.293-293, Article 293
Hauptverfasser: Nouri-Majalan, Nader, Masoumi, Roghayyeh, Halvani, Abolhasan, Moghaddasi, Sara
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Among the complications of extracorporeal shock wave lithotripsy are perinephric bleeding and hypertension. We describe the case of a 31-year-old Asian man with an unusual case of hemoptysis and lung contusion and cavitation with exudative plural effusion due to pulmonary trauma following false positioning of extracorporeal shock wave lithotripsy. Differential diagnoses included pneumonia and pulmonary emboli, but these diagnoses were ruled out by the uniformly negative results of a lung perfusion scan, Doppler ultrasound, and culture of bronchoalveolar lavage and plural effusion, and because our patient showed spontaneous improvement. False positioning of extracorporeal shock wave lithotripsy can cause lung trauma presenting as pulmonary contusion and cavitation with plural effusion.