Effectiveness Assessment of Bispectral Index Monitoring Compared with Conventional Monitoring in General Anesthesia: A Systematic Review and Meta-Analysis
. The Bispectral Index (BIS) is utilized to guide the depth of anesthesia monitoring during surgical procedures. However, conflicting results regarding the benefits of BIS for depth of anesthesia monitoring have been reported in numerous studies. The purpose of this meta-analysis and systematic revi...
Gespeichert in:
Veröffentlicht in: | Anesthesiology research and practice 2024-08, Vol.2024 (1), p.5555481 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | . The Bispectral Index (BIS) is utilized to guide the depth of anesthesia monitoring during surgical procedures. However, conflicting results regarding the benefits of BIS for depth of anesthesia monitoring have been reported in numerous studies. The purpose of this meta-analysis and systematic review was to assess the effectiveness of BIS for depth of anesthesia monitoring.
. A systematic search of Ovid-MEDLINE, Cochrane, and PubMed was conducted from inception to April 20, 2023. Clinical trial registers and grey literature were also searched, and reference lists of included studies, as well as related review articles, were manually reviewed.
. The inclusion criteria were randomized controlled trials without gender or age restrictions. The control groups used conventional monitoring, while the intervention groups utilized BIS monitoring. The exclusion criteria included duplicates, reviews, animal studies, unclear outcomes, and incomplete data.
. Two independent reviewers screened the literature, extracted data, and assessed methodological quality, with analyses conducted using R 4.0 software.
. Forty studies were included. In comparison to the conventional depth of anesthesia monitoring, BIS monitoring reduced the postoperative cognitive dysfunction risk (RR = 0.85, 95% CI: 0.73∼0.99,
= 0.04), shortened the eye-opening time (MD = -1.34, 95% CI: -2.06∼-0.61,
< 0.01), orientation recovery time (MD = -1.99, 95% CI: -3.62∼-0.36,
= 0.02), extubation time (MD = -2.54, 95% CI: -3.50∼-1.58,
< 0.01), and postanesthesia care unit stay time (MD = -7.11, 95% CI: -12.67∼-1.55,
= 0.01) and lowered the anesthesia drug dosage (SMD = -0.39, 95% CI: -0.63∼-0.15,
< 0.01).
. BIS can be used to effectively monitor the depth of anesthesia. Its use in general anesthesia enhances the effectiveness of both patient care and surgical procedures. |
---|---|
ISSN: | 1687-6962 1687-6970 |
DOI: | 10.1155/2024/5555481 |