Structural analysis of deep soil loosening machine MAS-65

Deep soil loosening machine MAS 65 is destined to work soil at depths exceeding 45 cm, thus the machine’s frame is subjected to loads which could affect its structural integrity. Within this paper a static structural analysis was performed on the machine’s 3D model using finite element method and st...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Matache, Mihai Gabriel, Oprescu, Remus Marius, Dumitru, Dragos Nicolae, Gheorghe, Gabriel Valentin, Cujbescu, Dan, Persu, Cătălin
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Deep soil loosening machine MAS 65 is destined to work soil at depths exceeding 45 cm, thus the machine’s frame is subjected to loads which could affect its structural integrity. Within this paper a static structural analysis was performed on the machine’s 3D model using finite element method and strain and stress distribution maps were created. Using the Von Mises stress map there were identified several critical points which could fail during normal exploitation conditions and which should be monitored by strain gages during field tests in order to prevent structural failure.
ISSN:2267-1242
2555-0403
2267-1242
DOI:10.1051/e3sconf/201911203034