Changes in Nerve Conduction Studies After Distal Radius Fracture Fixation Using a Volar Approach and Locked Plate
To determine whether there are changes in nerve conduction studies (NCS) of the median nerve after distal radius fracture (DRF) and to determine how operative fixation through a volar approach with a locking plate contributes to nerve conduction changes. We hypothesized that a considerable percentag...
Gespeichert in:
Veröffentlicht in: | Journal of hand surgery global online 2020-09, Vol.2 (5), p.286-289 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To determine whether there are changes in nerve conduction studies (NCS) of the median nerve after distal radius fracture (DRF) and to determine how operative fixation through a volar approach with a locking plate contributes to nerve conduction changes. We hypothesized that a considerable percentage of patients would have electrodiagnostic evidence of median neuropathy at the wrist after fracture, but fixation with a volar locked plate would not worsen the electrodiagnostic findings.
This was a prospective cohort study of 14 neurologically asymptomatic patients who underwent surgical treatment of an isolated DRF using a volar plate. All patients underwent surgery within 2 weeks of injury. On the day of surgery and at the 6-week follow-up, patients were clinically examined, Quick–Disabilities of the Arm, Shoulder, and Hand questionnaire was completed, and patients underwent NCS using a handheld device with the unaffected limb, which was used as a comparison. Preoperative and postoperative nerve function were compared with the unaffected limb as a baseline.
Patients without symptoms after DRF had a 28% incidence of prolonged latencies compared with reference values for the device used. Distal sensory latencies of the median nerve were 3.64 ± 0.32 ms in the unaffected arm, 3.76 ± 0.70 ms before surgery, and 3.81 ± 0.52 ms after surgery. Distal motor latencies of the median nerve were 3.91 ± 0.59, 3.60 ± 0.68, and 3.88 ± 0.36 ms in respective arms and time points. Quick–Disabilities of the Arm, Shoulder, and Hand scores improved from 77 before surgery to 46 at 6 weeks.
Asymptomatic patients may satisfy nerve conduction criteria for median neuropathy at the wrist after DRF; however, open reduction and treatment with a volar locked plate has no significant effect on NCS findings.
Prognostic II. |
---|---|
ISSN: | 2589-5141 2589-5141 |
DOI: | 10.1016/j.jhsg.2020.06.003 |