Second-Generation central venous catheter in the prevention of bloodstream infection: a systematic review

to evaluate the effectiveness and safety in the use of second-generation central venous catheters impregnated in clorhexidine and silver sulfadiazine when compared with other catheters, being them impregnated or not, in order to prevent the bloodstream infection prevention. systematic review with me...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Revista latino-americana de enfermagem 2016-01, Vol.24, p.e2722-e2722
Hauptverfasser: Stocco, Janislei Gislei Dorociaki, Hoers, Hellen, Pott, Franciele Soares, Crozeta, Karla, Barbosa, Dulce Aparecida, Meier, Marineli Joaquim
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:to evaluate the effectiveness and safety in the use of second-generation central venous catheters impregnated in clorhexidine and silver sulfadiazine when compared with other catheters, being them impregnated or not, in order to prevent the bloodstream infection prevention. systematic review with meta-analysis. Databases searched: MEDLINE, EMBASE, CINAHL, LILACS/SciELO, Cochrane CENTRAL; search in Congress Proceedings and records from Clinical Trials. 1.235 studies were identified, 97 were pre-selected and 4 were included. In catheter-related bloodstream infection, there was no statistical significance between second-generation impregnated catheter compared with the non-impregnated ones, absolute relative risk 1,5% confidence interval 95% (3%-1%), relative risk 0,68 (confidence interval 95%, 0,40-1,15) and number needed to treat 66. In the sensitivity analysis, there was less bloodstream infection in impregnated catheters (relative risk 0,50, confidence interval 95%, 0,26-0,96). Lower colonization, absolute relative risk 9,6% (confidence interval 95%, 10% to 4%), relative risk 0,51 (confidence interval 95% from 0,38-0,85) and number needed to treat 5. the use of second-generation catheters was effective in reducing the catheter colonization and infection when a sensitivity analysis is performed. Future clinical trials are suggested to evaluate sepsis rates, mortality and adverse effects. evaluar la efectividad y seguridad del uso de catéteres venosos centrales de segunda generación, impregnados en clorhexidina y sulfadiazina de plata, comparados con otros catéteres impregnados o no impregnados, para prevención de infección de la corriente sanguínea. revisión sistemática con metaanálisis. La búsqueda fue realizada en las bases: MEDLINE, EMBASE, CINAHL, LILACS/SciELO, Cochrane CENTRAL; fueron consultados anales de congresos y registros de ensayos clínicos. fueron identificados 1.235 estudios, 97 preseleccionados y cuatro incluidos. En la infección de la corriente sanguínea, relacionada al catéter, no hubo significación estadística entre catéter de segunda generación impregnado en comparación a los no impregnados, riesgo relativo absoluto 1,5%, intervalo de confianza 95% (3%-1%), riesgo relativo 0,68 (intervalo de confianza 95%, 0,40-1,15) y número necesario para tratar 66. En el análisis de sensibilidad, hubo disminución de la infección de la corriente sanguínea en los catéteres impregnados (riesgo relativo 0,50, intervalo de confianza 95%, 0,26-0,96). Reduc
ISSN:0104-1169
1518-8345
1518-8345
0104-1169
DOI:10.1590/1518-8345.0756.2722