Detection of High-Temperature Gas Leaks in Pipelines Using Schlieren Visualization

This paper investigates the application of Schlieren flow visualization for detecting leaks in pipelines carrying high-temperature fluids. Two experimental setups were constructed: one with a 25 mm PTFE tube featuring a 2 mm diameter perforation, and another with a 100 mm diameter pipe insulated wit...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied sciences 2024-09, Vol.14 (18), p.8567
Hauptverfasser: Park, Tae-Jin, Kim, Kwang-Yeon, Oh, Dong-Wook
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper investigates the application of Schlieren flow visualization for detecting leaks in pipelines carrying high-temperature fluids. Two experimental setups were constructed: one with a 25 mm PTFE tube featuring a 2 mm diameter perforation, and another with a 100 mm diameter pipe insulated with an aluminum jacket and featuring a 12 mm leak gap. A single-mirror-off-axis Schlieren system, employing a 150 mm diameter parabolic mirror, was used to visualize the leaks. The temperature of the leaking air varied between 20 and 100 °C, while the ambient temperature was maintained at 14 °C. To quantify the leaks, the coefficient of variation for pixel intensity within the leak region was calculated. Results showed that for the PTFE tube, leaks became detectable when the temperature difference exceeded 34 °C, with the coefficient of variation surpassing 0.1. However, in the insulated pipe, detecting clear leak patterns was challenging. This research demonstrates the potential of Schlieren visualization as a valuable tool in enhancing pipeline leak detection.
ISSN:2076-3417
2076-3417
DOI:10.3390/app14188567