Computational fluid dynamics assessment of effect of different openings configurations on the thermal environment of a facility for coffee wet processing

This study aimed to analyze the effect of the area size and location of openings for natural ventilation on the temperature and relative humidity inside a typological facility for coffee wet processing that have been using in Colombia and some South America Countries as well, with mechanical drying...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Agricultural Engineering 2020-03, Vol.51 (1), p.21-26
Hauptverfasser: Osorio Hernandez, Robinson, Osorio Saraz, Jairo Alexander, Oliveira, Keller Sullivan, Aristizabal, Ivan Dario, Arango, Julio Cesar
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study aimed to analyze the effect of the area size and location of openings for natural ventilation on the temperature and relative humidity inside a typological facility for coffee wet processing that have been using in Colombia and some South America Countries as well, with mechanical drying inside, using modeling with computational fluid dynamics modeling, in order to find the best suitable condition for preserve the quality of the coffee parchment. A significant effect was found regarding the area and location of the openings for natural ventilation on the internal hygrothermal environment, but no significant effect was found on the temperature. It was also found that the chimney effect plays a decisive role in the mass transfer of water vapor and heat to the outside of the building, and helping to maintain a suitable internal environment for the preservation of coffee.
ISSN:1974-7071
2239-6268
DOI:10.4081/jae.2020.892