Resistance measurement for monitoring bending cracks in steel fiber concrete beams test

Cracks will inevitably occur in concrete structural during the normal use phase due to load action, fatigue effect, and environmental corrosion. Concrete resistance can reflect some internal concrete damage. In this work, three-point bending tests were performed on concrete beams. We simultaneously...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Alexandria engineering journal 2023-03, Vol.66, p.691-699
Hauptverfasser: Jiang, Bolin, Wu, Shanshan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Cracks will inevitably occur in concrete structural during the normal use phase due to load action, fatigue effect, and environmental corrosion. Concrete resistance can reflect some internal concrete damage. In this work, three-point bending tests were performed on concrete beams. We simultaneously measured the concrete beam resistance before and after cracking to investigate the feasibility of resistance measurement for achieving self-monitoring of concrete cracking and crack development. This work provides a methodology for the monitoring of engineering structures. It establishes a quantitative reference for the relationship between the number of steel fibers used and their conductive and mechanically sensitive properties.
ISSN:1110-0168
DOI:10.1016/j.aej.2022.10.074