Effects of antibiotic-free pig rearing on ammonia emissions from five pairs of swine rooms in a wean-to-finish experiment

Antibiotic use and ammonia (NH3) emissions during animal production are two environmental issues of worldwide concern. However, the role of antibiotics on NH3 emissions is still unknown. This study evaluated the effects of rearing pigs without antibiotics on NH3 emissions from a swine experimental b...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Environment international 2019-10, Vol.131, p.104931, Article 104931
Hauptverfasser: Ni, Ji-Qin, Shi, Chen, Liu, Shule, Richert, Brian T., Vonderohe, Caitlin E., Radcliffe, John S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Antibiotic use and ammonia (NH3) emissions during animal production are two environmental issues of worldwide concern. However, the role of antibiotics on NH3 emissions is still unknown. This study evaluated the effects of rearing pigs without antibiotics on NH3 emissions from a swine experimental building starting with 657 piglets during a wean-to-finish production cycle of 154 days. Pigs were reared in two groups of 10 rooms that were divided into five 2-room pairs (P1–P5) and fed in nine dietary phases. Each pair consisted of one room without antibiotics (no antibiotics in the diet, water, or injectable) and another room as a positive control. Control animals were fed diets containing carbadox-10 (phases 1–4), chlortetracycline (CTC, phase 5), lincomix (phases 6–7), and tylan 40 (phases 8–9). Temperatures in the pig living space and the under-floor manure pit headspace were continuously measured. Ventilation rates at all wall fans and pit fans were obtained by continuous monitoring. Ammonia concentrations in the wall and pit fan exhaust air, and in room inlet air were measured with two multi-gas monitors. Only days that contained at least 18 h of data each day were validated and used. The study generated 1337 room-days of valid data of NH3 emission rates, with a data completeness of 88.6%. Daily mean NH3 emission patterns demonstrated large variations between the paired rooms and among different pairs. Within the individual 2-room pairs, no NH3 emission differences were found in P1 (rooms 1 and 2, p = 0.34) and P2 (rooms 3 and 4, p = 0.44). Significant differences were found in P3–P5 (p 
ISSN:0160-4120
1873-6750
DOI:10.1016/j.envint.2019.104931