External root resorption with the self-ligating Damon system—a retrospective study
Background The aim of this study was to compare the degree of external apical root resorption (EARR) in patients treated with self-ligating Damon appliances and with conventional preadjusted appliances. Methods The sample comprised 52 patients, divided into two groups. Group 1 consisted of 25 patien...
Gespeichert in:
Veröffentlicht in: | Progress in orthodontics 2016-07, Vol.17 (1), p.20-20, Article 20 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
The aim of this study was to compare the degree of external apical root resorption (EARR) in patients treated with self-ligating Damon appliances and with conventional preadjusted appliances.
Methods
The sample comprised 52 patients, divided into two groups. Group 1 consisted of 25 patients treated with self-ligating Damon appliances, with an initial age of 16.04 years, final age of 18.06 years, and treatment time of 2.02 years. Group 2 consisted of 27 patients, treated with conventional preadjusted appliances, with an initial age of 16.77 years, final age of 18.47 years and treatment time of 1.70 years. The groups were matched regarding the initial and final ages, treatment time, type of malocclusion, and treatment protocol without extractions. Root resorption was evaluated on periapical radiographs of the maxillary and mandibular incisors at the end of orthodontic treatment with the scores of Levander and Malmgren. Intergroup comparisons of root resorption were performed with Mann-Whitney tests.
Results
No significant difference in the degree of root resorption between the two groups was found.
Conclusions
Similar degrees of resorption can be expected after non-extraction treatment with Damon self-ligating or conventional preadjusted appliances. |
---|---|
ISSN: | 2196-1042 1723-7785 2196-1042 |
DOI: | 10.1186/s40510-016-0133-1 |