The SPARC Water Vapor Assessment II: assessment of satellite measurements of upper tropospheric humidity
Nineteen limb-viewing data sets (occultation, passive thermal, and UV scattering) and two nadir upper tropospheric humidity (UTH) data sets are intercompared and also compared to frost-point hygrometer balloon sondes. The upper troposphere considered here covers the pressure range from 300–100 hPa....
Gespeichert in:
Veröffentlicht in: | Atmospheric measurement techniques 2022-06, Vol.15 (11), p.3377-3400 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Nineteen limb-viewing data sets (occultation, passive thermal, and UV scattering) and two nadir
upper tropospheric humidity (UTH) data sets are intercompared and also compared to frost-point hygrometer
balloon sondes. The upper troposphere considered here covers the pressure range from 300–100 hPa.
UTH is a challenging measurement, because concentrations
vary between 2–1000 ppmv (parts per million by volume), with sharp changes in vertical
gradients near the tropopause. Cloudiness in this region
also makes the measurement challenging. The atmospheric temperature is also highly
variable ranging from 180–250 K. The assessment of satellite-measured UTH
is based on coincident comparisons with balloon frost-point hygrometer
sondes, multi-month mapped comparisons, zonal mean time series comparisons, and
coincident satellite-to-satellite comparisons. While the satellite fields show
similar features in maps and time series, quantitatively they can differ by a
factor of 2 in concentration, with strong dependencies on the amount of UTH.
Additionally, time-lag response-corrected Vaisala RS92 radiosondes are
compared to satellites and the frost-point hygrometer measurements. In summary,
most satellite data sets reviewed here show on average ∼30 % agreement
amongst themselves and frost-point data but with an additional ∼30 %
variability about the mean bias. The Vaisala RS92 sonde, even with a time-lag
correction, shows poor behavior for pressures less than 200 hPa. |
---|---|
ISSN: | 1867-8548 1867-1381 1867-8548 |
DOI: | 10.5194/amt-15-3377-2022 |