Personalized Deep Learning Model for Clinical Target Volume on Daily Cone Beam Computed Tomography in Breast Cancer Patients
Herein, we developed a deep learning algorithm to improve the segmentation of the clinical target volume (CTV) on daily cone beam computed tomography (CBCT) scans in breast cancer radiation therapy. By leveraging the Intentional Deep Overfit Learning (IDOL) framework, we aimed to enhance personalize...
Gespeichert in:
Veröffentlicht in: | Advances in radiation oncology 2024-10, Vol.9 (10), p.101580, Article 101580 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Herein, we developed a deep learning algorithm to improve the segmentation of the clinical target volume (CTV) on daily cone beam computed tomography (CBCT) scans in breast cancer radiation therapy. By leveraging the Intentional Deep Overfit Learning (IDOL) framework, we aimed to enhance personalized image-guided radiation therapy based on patient-specific learning.
We used 240 CBCT scans from 100 breast cancer patients and employed a 2-stage training approach. The first stage involved training a novel general deep learning model (Swin UNETR, UNET, and SegResNET) on 90 patients. The second stage used intentional overfitting on the remaining 10 patients for patient-specific CBCT outputs. Quantitative evaluation was conducted using the Dice Similarity Coefficient (DSC), Hausdorff Distance (HD), mean surface distance (MSD), and independent samples t test with expert contours on CBCT scans from the first to 15th fractions.
IDOL integration significantly improved CTV segmentation, particularly with the Swin UNETR model (P values < .05). Using patient-specific data, IDOL enhanced the DSC, HD, and MSD metrics. The average DSC for the 15th fraction improved from 0.9611 to 0.9819, the average HD decreased from 4.0118 mm to 1.3935 mm, and the average MSD decreased from 0.8723 to 0.4603. Incorporating CBCT scans from the initial treatments and first to third fractions further improved results, with an average DSC of 0.9850, an average HD of 1.2707 mm, and an average MSD of 0.4076 for the 15th fraction, closely aligning with physician-drawn contours.
Compared with a general model, our patient-specific deep learning-based training algorithm significantly improved CTV segmentation accuracy of CBCT scans in patients with breast cancer. This approach, coupled with continuous deep learning training using daily CBCT scans, demonstrated enhanced CTV delineation accuracy and efficiency. Future studies should explore the adaptability of the IDOL framework to diverse deep learning models, data sets, and cancer sites. |
---|---|
ISSN: | 2452-1094 2452-1094 |
DOI: | 10.1016/j.adro.2024.101580 |