Comparative evaluation of dural venous sinuses and cerebral veins using contrast-enhanced spoiled gradient recalled echo and time-of-flight magnetic resonance venography
AbstractBackground/Aims:In the present study, dural venous sinuses and cerebral veins were examined using 3D SPGR MRV and 2D TOF MRV. These methods were compared in terms of detectability of venous structures and their diameters. Methods:A total of 110 patients(66 female and 44 male) who had contras...
Gespeichert in:
Veröffentlicht in: | Çağdaş tıp dergisi 2019-09, Vol.9 (3), p.214-221 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | AbstractBackground/Aims:In the present study, dural venous sinuses and
cerebral veins were examined using 3D SPGR MRV and 2D TOF MRV. These methods
were compared in terms of detectability of venous structures and their
diameters. Methods:A total of 110 patients(66 female and 44 male) who
had contrast-enhanced 3D SPGR MRV and 2D TOF MRV examinations using a 1.5 T MRI
machine in May 2008-June 2011 period were included in the present study.
Diameters of dural venous sinuses and veins were measured at three different
planes at a position 1cm distal to the site they drained into, and average
values were used. Both MRV methods were compared to reveal whether the
diameters calculated were different in age groups and between genders.Results:SSS, bilateral TS’s, right sigmoid sinus, Galen
vein and bilateral ICV’s all could be determined using 3D SPGR MRV. Not all
dural venous sinuses and veins other than right sigmoid sinus could be
visualized in all patients using 2D TOF MRV.There were significant differences
between the two examinations for SSS and ISS, bilateral TS and sigmoid sinuses,
SS, bilateral Labbe and ICV and Galen vein diameters(p |
---|---|
ISSN: | 2667-7180 2667-7180 |
DOI: | 10.16899/jcm.556044 |