Combined Loop-Mediated Isothermal Amplification Assays for Rapid Detection and One-Step Differentiation of Campylobacter jejuni and Campylobacter coli in Meat Products

A loop-mediated isothermal amplification (LAMP) assay system was established, allowing rplD gene-based simultaneous detection of Campylobacter jejuni and Campylobacter coli in enriched meat products. Additionally, one-step differentiation of target species on agar plates was enabled by cdtC gene- an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Frontiers in microbiology 2021-06, Vol.12, p.668824-668824
Hauptverfasser: Kreitlow, Antonia, Becker, André, Ahmed, Marwa F. E., Kittler, Sophie, Schotte, Ulrich, Plötz, Madeleine, Abdulmawjood, Amir
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A loop-mediated isothermal amplification (LAMP) assay system was established, allowing rplD gene-based simultaneous detection of Campylobacter jejuni and Campylobacter coli in enriched meat products. Additionally, one-step differentiation of target species on agar plates was enabled by cdtC gene- and gyrA gene-based duplex LAMP. Both the rplD and cdtC – gyrA LAMP assays amplified the target sequences in all 62 C. jejuni and 27 C. coli strains used for determining inclusivity and revealed 100% exclusivity toward 85 tested non-target species. Throughout the entire experiments, C. jejuni and C. coli strains were 100% distinguishable by melting curves of cdtC and gyrA LAMP products. After 24-h enrichment, the rplD LAMP assay reliably detected initial inoculation levels of 10–100 CFU/g in artificially contaminated minced meat. Investigation of naturally contaminated meat samples revealed a diagnostic accuracy of 95% toward real-time PCR and 94.1% toward the standard culture method applying the 24-h incubation period. Diagnostic sensitivity and specificity, and positive and negative predictive values were 89.8, 100, 100, and 91.2%, respectively, when measured against real-time PCR, and 89.6, 98.1, 97.7, and 91.2%, respectively, when measured against the standard culture method. After 48-h enrichment, the detection limit of the rplD LAMP assay improved to initial inoculation levels of 1–10 CFU/g in artificially contaminated minced meat. Applying the 48-h incubation period on naturally contaminated meat samples resulted in 100% concordant results between rplD LAMP, real-time PCR, and the standard culture method. The established LAMP assay system was proved to be suitable for rapid meat sample screening. Furthermore, it constitutes a promising tool for investigating other Campylobacter sources and could therefore make a valuable contribution to protect consumers from foodborne illness.
ISSN:1664-302X
1664-302X
DOI:10.3389/fmicb.2021.668824