Simultaneous determination of pioglitazone and candesartan in human plasma by LC-MS/MS and its application to a human pharmacokinetic study
A simple and rapid liquid chromatography-tandem mass spectrometric(LC-MS/MS) assay method has been developed and fully validated for simultaneous quantification of pioglitazone and candesartan in human plasma.Irbesartan was used as an internal standard.The analytes were extracted from human plasma s...
Gespeichert in:
Veröffentlicht in: | Journal of pharmaceutical analysis 2012-06, Vol.2 (3), p.167-173 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A simple and rapid liquid chromatography-tandem mass spectrometric(LC-MS/MS) assay method has been developed and fully validated for simultaneous quantification of pioglitazone and candesartan in human plasma.Irbesartan was used as an internal standard.The analytes were extracted from human plasma samples by solid-phase extraction technique using a Strata-X 33 mm polymeric sorbent.The reconstituted samples were chromatographed on a C18 column by using a 80:20(v/v) mixture of acetonitrile and 0.1% formic aci... |
---|---|
ISSN: | 2095-1779 2214-0883 |
DOI: | 10.1016/j.jpha.2012.01.002 |