Simplified implementation of 3L-SVPWM algorithm and neutral-point balancing
The traditional implementation method of the three-level space vector pulse width modulation (3L-SVPWM) needs multiple region judgment and a lot of trigonometric function operation, which has a large amount of calculation and increases the burden of the microprocessor. Therefore, a simplified implem...
Gespeichert in:
Veröffentlicht in: | Energy reports 2022-08, Vol.8, p.453-460 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The traditional implementation method of the three-level space vector pulse width modulation (3L-SVPWM) needs multiple region judgment and a lot of trigonometric function operation, which has a large amount of calculation and increases the burden of the microprocessor. Therefore, a simplified implementation method of the 3L-SVPWM algorithm is suggested to reduce the complexity and avoid trigonometric function calculation. The method is simply completed by comparing and doing some addition and subtraction operations on the abc-axis coordinates of the reference vector. And the neutral-point balancing is achieved by directly changing the action time of the three-phase bridge arms. Hence, the complexity of the implementation of the 3L-SVPWM algorithm is remarkably reduced. Finally, the correctness of the simplified implementation method is verified by simulation experiments. |
---|---|
ISSN: | 2352-4847 2352-4847 |
DOI: | 10.1016/j.egyr.2022.02.185 |