Developing and Testing the Air Cooling System of a Combined Climate Control Unit Used in Pig Farming
This article presents the results of developing and testing the air-cooling system of a combined climate control unit used in pig farming. The authors have found a water-evaporative system to be the most efficient for cooling the air supply. Cooling systems of this type consume 0.003 kW/kW of electr...
Gespeichert in:
Veröffentlicht in: | Agriculture (Basel) 2023-01, Vol.13 (2), p.334 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This article presents the results of developing and testing the air-cooling system of a combined climate control unit used in pig farming. The authors have found a water-evaporative system to be the most efficient for cooling the air supply. Cooling systems of this type consume 0.003 kW/kW of electric power to produce 1 kW of cold. Based on the developed mathematical model for water-evaporative cooling in the combined climate control unit, the authors have determined that an air supply with a temperature of 31.2 °C and a relative humidity of 30.4% can be cooled by 8.3 °C when saturated with moisture to a relative humidity of 90.0% (by 11.7 °C at 100%). Experimental studies of the cooling system confirmed the theoretically obtained data. |
---|---|
ISSN: | 2077-0472 2077-0472 |
DOI: | 10.3390/agriculture13020334 |