The effect of recombinant versus plasma-derived von Willebrand factor on prolonged PFA closure times in ECMO patients with acquired von Willebrand syndrome - an observational study

Extracorporeal membrane oxygenation (ECMO) is applied in patients with respiratory or cardiopulmonary failure, but bleeding is a frequent complication contributing to the high mortality rates in this patient collective. A major factor predisposing patients to bleeding events is an acquired von Wille...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Thrombosis journal 2023-01, Vol.21 (1), p.4-4, Article 4
Hauptverfasser: Büchsel, Martin, Geisen, Ulrich, Beckenkamp, Clara, Wengenmayer, Tobias, Zieger, Barbara, Westermann, Dirk, Siegel, Patrick M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Extracorporeal membrane oxygenation (ECMO) is applied in patients with respiratory or cardiopulmonary failure, but bleeding is a frequent complication contributing to the high mortality rates in this patient collective. A major factor predisposing patients to bleeding events is an acquired von Willebrand syndrome (aVWS). So far, specific treatment options for this phenomenon are lacking. In hereditary von Willebrand disease (VWD), treatment with recombinant or plasma-derived von Willebrand factor (rVWF or pVWF) is common practice. Closure time measured by the Platelet Function Analyser-200 (PFA-200) is an established assay to detect defects in primary hemostasis and the method is useful to monitor the effect of hemostatic therapy. The aim of this study was to assess the effect of recombinant (rVWF) vs. plasma-derived von Willebrand factor (pVWF) on closure times measured by PFA in blood obtained from ECMO patients with aVWS. Blood was sampled from thirteen patients receiving extracorporeal membrane oxygenation and three patients with hereditary VWD. Diagnosis of aVWS was made by conventional coagulation parameters and by multimeric structure analysis. PFA analysis of blood spiked with rVWF or pVWF was performed. Thirteen patients receiving ECMO were recruited. Ten patients survived and three patients suffered major bleeding complications. PFA closure times in ECMO patients with aVWS spiked with rVWF were significantly shorter at all concentrations than with pVWF (e.g., rVWF vs. pVWF: 1 U/ml: 150.4 ± 21.7 s vs. 263.8 ± 11.7 s; 4 U/ml: 97.8 ± 9.8 s vs. 195.8 ± 15.4 s, p
ISSN:1477-9560
1477-9560
DOI:10.1186/s12959-022-00448-1