Digital technique to analyze the wear of screw-retained implant supported metal-ceramic dental prostheses and natural tooth as antagonist: a pilot study
The aim of this study was to describe a novel digital technique to analyze the wear of screw-retained implant-supported metal-ceramic dental prostheses and natural tooth as antagonist.Materials and methods Ten patients were consecutively included to rehabilitate partial edentulism by dental implants...
Gespeichert in:
Veröffentlicht in: | BMC oral health 2024-02, Vol.24 (1), p.177-177, Article 177 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of this study was to describe a novel digital technique to analyze the wear of screw-retained implant-supported metal-ceramic dental prostheses and natural tooth as antagonist.Materials and methods Ten patients were consecutively included to rehabilitate partial edentulism by dental implants. Both the screw-retained implant-supported metal-ceramic dental prostheses and the natural tooth as antagonist were submitted to a digital impression through an intraoral scan to generate a Standard Tessellation Language digital file preoperatively (STL1), at 3 months (STL2), and 6 months (STL3) follow-up. Afterwards, an alignment procedure of the digital files (STL1-STL3) was performed on a reverse engineering morphometric software (3D Geomagic Capture Wrap) and volume changes at the screw-retained implant-supported metal-ceramic dental prostheses and the natural tooth as antagonist were analyzed using Student's t-test. Moreover, Gage R&R statistical analysis was conducted to analyze the repeatability and reproducibility of the digital technique.Results Gage R&R showed a variability attributable to the digital technique of 3.8% (among the measures of each operator) and 4.5% (among operators) of the total variability; resulting repeatable and reproducible, since the variabilities were under 10%. In addition, statistically significant differences were shown at the wear volume (μm
) of both the natural tooth as antagonist (p < 0.0001) and the screw-retained implant-supported metal-ceramic dental prostheses between 3- and 6-months follow-up (p = 0.0002).Conclusion The novel digital measurement technique results repeatable and reproducible to analyze the wear of screw-retained implant-supported metal-ceramic dental prostheses and natural tooth as antagonist. |
---|---|