Approach for Routine Analytical Detection of Beeswax Adulteration Using FTIR-ATR Spectroscopy

Although beeswax adulteration represents one of the main beeswax quality issues, there are still no internationally standardised analytical methods for routine quality control. The objective of this study was to establish an analytical procedure suitable for routine detection of beeswax adulteration...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Apicultural Science 2015-12, Vol.59 (2), p.37-49
Hauptverfasser: Svečnjak, Lidija, Goran BaranoviÄ, Marko VincekoviÄ, SaÅ¡a Prđun, Dragan Bubalo, Ivana Tlak Gajger
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Although beeswax adulteration represents one of the main beeswax quality issues, there are still no internationally standardised analytical methods for routine quality control. The objective of this study was to establish an analytical procedure suitable for routine detection of beeswax adulteration using FTIR-ATR spectroscopy. For the purpose of this study, reference IR spectra of virgin beeswax, paraffin, and their mixtures containing different proportions of paraffin (5 - 95%), were obtained. Mixtures were used for the establishment of calibration curves. To determine the prediction strength of IR spectral data for the share of paraffin in mixtures, the Partial Least Squares Regression method was used. The same procedure was conducted on beeswax-beef tallow mixtures. The model was validated using comb foundation samples of an unknown chemical background which had been collected from the international market (n = 56). Selected physico-chemical parameters were determined for comparison purposes. Results revealed a strong predictive power (R² = 0.999) of IR spectra for the paraffin and beef tallow share in beeswax. The results also revealed that the majority of the analysed samples (89%) were adulterated with paraffin; only 6 out of 56 (11%) samples were identified as virgin beeswax, 28% of the samples exhibited a higher level of paraffin adulteration (>46% of paraffin), while the majority of the analysed samples (50%) were found to be adulterated with 5 - 20% of paraffin. These results indicate an urgent need for routine beeswax authenticity control. In this study, we demonstrated that the analytical approach defining the standard curves for particular adulteration levels in beeswax, based on chemometric modelling of specific IR spectral region indicative for adulteration, enables reliable determination of the adulterant proportions in beeswax.
ISSN:2299-4831
2299-4831
DOI:10.1515/jas-2015-0018