Serological Assays for Assessing Postvaccination SARS-CoV-2 Antibody Response

Serological assays for measuring severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies have crucial applications in the control and surveillance of the current COVID-19 pandemic. A large number of such assays have been developed and are now commercially available. However, there ar...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Microbiology spectrum 2021-10, Vol.9 (2), p.e0073321-e0073321
Hauptverfasser: Mahmoud, Sally A, Ganesan, Subhashini, Naik, Shivaraj, Bissar, Safaa, Zamel, Isra Al, Warren, KN, Zaher, Walid A, Khan, Gulfaraz
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Serological assays for measuring severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies have crucial applications in the control and surveillance of the current COVID-19 pandemic. A large number of such assays have been developed and are now commercially available. However, there are limited studies evaluating the performance of these tests. We evaluated the performances of the following six commercially available serological assays for detecting SARS-CoV-2 antibodies: (i) Genscript cPass surrogate virus neutralization test (Genscript cPass), (ii) Diasorin-SARS-CoV-2 S1/S2 IgG detection (Diasorin-S1/S2 IgG), (iii) Alinity SARS-CoV-2 IgG II (Alinity IgG II), (iv) Diasorin-SARS-CoV-2 TrimericS IgG (Diasorin-TrimericS IgG), (v) Roche Elecsys anti-SARS-CoV-2-cobas (Roche Elecsys), and (vi) AESKU enzyme linked immunosorbent assay (AESKULISA). The results of these tests were compared against the gold standard plaque reduction neutralization test (PRNT). Roche Elecsys had the highest sensitivity, and the Genscript cPass had the highest specificity. Diasorin-TrimericS IgG had the best overall performance with the highest agreement with the PRNT results. Parallel testing of Genscript cPass with Diasorin-TrimericS IgG and Diasorin-S1/S2 IgG had the optimum performance. Based on the receiver operating characteristic (ROC) curve, lowering the cutoff from 30% to 20% in the Genscript cPass significantly increased the sensitivity and the overall agreement with the PRNT results. Commercially available serological assays are good alternatives to the standard PRNT. However, further studies on larger sample numbers are required for optimization of the assay cutoff values and for evaluation of cost effectiveness. IMPORTANCE Commercial serological assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are now widely available. This study adds new knowledge regarding the optimization of these assays for evaluating postvaccination antibodies status. It highlights the positive and negative aspects of each assay in terms of sensitivity, specificity, and positive and negative predictive values, compared to the gold standard neutralization test. When using serological assays to assess postvaccine immune status, a balance of all parameters needs to be considered and not simply the high specificity. This balance is particularly relevant in the current situation where countries are aiming to mass vaccinate their populations and bring this pandemic unde
ISSN:2165-0497
2165-0497
DOI:10.1128/Spectrum.00733-21