Preliminary mechanical evaluation of two novel veterinary angle-stable-threaded interlocking nail systems

The interlocking nail represents an excellent option as a surgical approach to treat fractures in long bones in veterinary medicine. However, failures were reported mainly due to a slack present in the interface of the rod with the screws. The present study tested and mechanically compare axial comp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ciência rural 2022-01, Vol.52 (6)
Hauptverfasser: Nóbrega, Jordana da Costa, Lucena, Dayvid Vianêis Farias de, Minto, Bruno Watanabe, Dias, Luis Gustavo Gosuen Gonçalves
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The interlocking nail represents an excellent option as a surgical approach to treat fractures in long bones in veterinary medicine. However, failures were reported mainly due to a slack present in the interface of the rod with the screws. The present study tested and mechanically compare axial compression loads of two novel models of stable angle interlocking nails with threaded holes. Among the two models, one was uniplanar and the other was multiplanar with orthogonally arranged distal holes. Twenty-one specimens made of polylactic acid were used for the implantation of interlocking nail´s rods, divided into three groups: conventional interlocking nail (G1), novel interlocking nail with a stable angle with holes arranged in a single plane (G2), and novel interlocking nail with a stable angle in two planes, with the penultimate hole at 90 degrees from the others (G3). Biomechanical tests were performed using axial, cyclic, and destructive compression load for comparison between them. All the specimens showed plastic deformation in the screws after destructive tests, in both proximal and distal sides, being highly intense in G1. G2 and G3 of the stable angle rods supported higher loads than G1 in all tests performed (P0.05). The initial hypothesis that the novel models would provide increased stability was confirmed; however, no differences were demonstrated between them. The screw locking system on the rods allowed high resistance values in the tests performed, proving to be effective and potentially applicable in real clinical situations. RESUMO: A haste intramedular bloqueada representa excelente opção para abordagem cirúrgica de fraturas em ossos longos na medicina veterinária. Todavia, falhas decorrentes principalmente de “folga” presente na interface da haste com os parafusos foram relatadas. O presente estudo teve como objetivo testar e comparar mecanicamente, por cargas de compressão axial, dois novos modelos de haste intramedular bloqueada de ângulo estável com orifícios roscados, sendo uma delas uniplanar e outra multiplanar com orifícios distais dispostos ortogonalmente. Vinte e um corpos de prova confeccionados em ácido polilático (PLA) foram utilizados para implantação das hastes intramedulares bloqueadas, divididos em três grupos: Haste bloqueada convencional (G1); haste bloqueada nova de ângulo estável com orifícios dispostos em único plano (G2); haste bloqueada nova de
ISSN:0103-8478
1678-4596
1678-4596
DOI:10.1590/0103-8478cr20200892