Evaluation of Pictorial Dietary Assessment Tool for Hospitalized Patients with Diabetes: Cost, Accuracy, and User Satisfaction Analysis

Although nutritional screening and dietary monitoring in clinical settings are important, studies on related user satisfaction and cost benefit are still lacking. This study aimed to: (1) elucidate the cost of implementing a newly developed dietary monitoring tool, the Pictorial Dietary Assessment T...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nutrients 2017-12, Vol.10 (1), p.27
Hauptverfasser: Budiningsari, Dwi, Shahar, Suzana, Abdul Manaf, Zahara, Mohd Nordin, Nor Azlin, Susetyowati, Susetyowati
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Although nutritional screening and dietary monitoring in clinical settings are important, studies on related user satisfaction and cost benefit are still lacking. This study aimed to: (1) elucidate the cost of implementing a newly developed dietary monitoring tool, the Pictorial Dietary Assessment Tool (PDAT); and (2) investigate the accuracy of estimation and satisfaction of healthcare staff after the use of the PDAT. A cross-over intervention study was conducted among 132 hospitalized patients with diabetes. Cost and time for the implementation of PDAT in comparison to modified Comstock was estimated using the activity-based costing approach. Accuracy was expressed as the percentages of energy and protein obtained by both methods, which were within 15% and 30%, respectively, of those obtained by the food weighing. Satisfaction of healthcare staff was measured using a standardized questionnaire. Time to complete the food intake recording of patients using PDAT (2.31 ± 0.70 min) was shorter than when modified Comstock (3.53 ± 1.27 min) was used ( < 0.001). Overall cost per patient was slightly higher for PDAT (United States Dollar 0.27 ± 0.02) than for modified Comstock (USD 0.26 ± 0.04 ( < 0.05)). The accuracy of energy intake estimated by modified Comstock was 10% lower than that of PDAT. There was poorer accuracy of protein intake estimated by modified Comstock (71%) ( < 0.05). Mean user satisfaction of healthcare staff was significantly higher for PDAT than that for modified Comstock ( < 0.05). PDAT requires a shorter time to be completed and was rated better than modified Comstock.
ISSN:2072-6643
2072-6643