Thermal diffusivity measurement of copper nanofluid using pulsed laser thermal lens technique

The pulsed laser thermal lens technique was used to study the thermal diffusivity of fluids containing copper nanoparticles (Cu-NPs) prepared by γ -irradiation method. The samples were prepared for the different concentrations of Cu precursor at 20.KGy dose. A Q-switched Nd-YAG pulsed laser of wavel...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the European Optical Society. Rapid publications 2012-01, Vol.7, p.12022
Hauptverfasser: Zamiri, R., Azmi, B. Z., Shahril Husin, M., Zamiri, G., Ahangar, H. A., Rizwan, Z.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The pulsed laser thermal lens technique was used to study the thermal diffusivity of fluids containing copper nanoparticles (Cu-NPs) prepared by γ -irradiation method. The samples were prepared for the different concentrations of Cu precursor at 20.KGy dose. A Q-switched Nd-YAG pulsed laser of wavelength 532.nm was used as an excitation source and He-Ne laser was used as a probe beam in the present thermal lens experiment. It was found that the thermal diffusivity of the solution depends on the density of Cu-NPs.
ISSN:1990-2573
1990-2573
DOI:10.2971/jeos.2012.12022