Blood-based host biomarker diagnostics in active case finding for pulmonary tuberculosis: A diagnostic case-control study

There is a need to identify scalable tuberculosis screening strategies among high burden populations. The WHO has identified a non-sputum-based triage test as a development priority. We performed a diagnostic case-control study of point-of-care C-reactive protein (CRP) and Prototype-Xpert-MTB-Host-R...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:EClinicalMedicine 2021-03, Vol.33, p.100776-100776, Article 100776
Hauptverfasser: Moreira, Flora Martinez Figueira, Verma, Renu, Pereira dos Santos, Paulo Cesar, Leite, Alessandra, da Silva Santos, Andrea, de Araujo, Rafaele Carla Pivetta, da Silva, Bruna Oliveira, de Sá Queiroz, Júlio Henrique Ferreira, Persing, David H., Södersten, Erik, Gnanashanmugam, Devasena, Khatri, Purvesh, Croda, Julio, Andrews, Jason R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:There is a need to identify scalable tuberculosis screening strategies among high burden populations. The WHO has identified a non-sputum-based triage test as a development priority. We performed a diagnostic case-control study of point-of-care C-reactive protein (CRP) and Prototype-Xpert-MTB-Host-Response (Xpert-MTB-HR) assays in the context of a mass screening program for tuberculosis in two prisons in Brazil. All incarcerated individuals irrespective of symptoms were screened by sputum Xpert MTB/RIF and sputum culture. Among consecutive, Xpert MTB/RIF or culture-confirmed cases and Xpert MTB/RIF and culture-negative controls, CRP was quantified in serum by a point-of-care assay (iChroma-II) and a 3-gene expression score was quantified from whole blood using the Xpert-MTB-HR cartridge. We evaluated receiver operating characteristic area under the curve (AUC) and assessed specificity at 90% sensitivity and sensitivity at 70% specificity, consistent with WHO target product profile (TPP) benchmarks. Two hundred controls (no TB) and 100 culture- or Xpert MTB/RIF-positive tuberculosis cases were included. Half of tuberculosis cases and 11% of controls reported any tuberculosis symptoms. AUC for CRP was 0·79 (95% CI: 0·73–0·84) and for Xpert-MTB-HR was 0·84 (95% CI: 0·79–0·89). At 90% sensitivity, Xpert-MTB-HR had significantly higher specificity (53·0%, 95% CI: 45·0–69·0%) than CRP (28·1%, 95% CI: 20·2–41·8%) (p = 0·003), both well below the TPP benchmark of 70%. Among individuals with medium or high sputum Xpert MTB/RIF semi-quantitative load, sensitivity (at 70% specificity) of CRP (90·3%, 95% CI: 74·2–98·0) and Xpert-MTB-HR (96·8%, 95% CI: 83·3–99·9%) was higher. For active case finding in this high tuberculosis-burden setting, CRP and Xpert-MTB-HR did not meet TPP benchmarks for a triage test. However, Xpert-MTB-HR was highly sensitive in detecting individuals with medium or high sputum bacillary burden. National Institutes of Health (R01 AI130058 and R01 AI149620) and Brazilian National Council for Scientific and Technological Development (CNPq-404182/2019-4).
ISSN:2589-5370
2589-5370
DOI:10.1016/j.eclinm.2021.100776