CO₂ Selective Potentiometric Sensor in Thick-film Technology
A potentiometric sensor device based on screen-printed Nasicon films was investigated. In order to transfer the promising sensor concept of an open sodium titanate reference to thick film technology, "sodium-rich" and "sodium-poor" formulations were compared. While the "sodi...
Gespeichert in:
Veröffentlicht in: | Sensors (Basel, Switzerland) Switzerland), 2008-08, Vol.8 (8), p.4774-4785 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A potentiometric sensor device based on screen-printed Nasicon films was investigated. In order to transfer the promising sensor concept of an open sodium titanate reference to thick film technology, "sodium-rich" and "sodium-poor" formulations were compared. While the "sodium-rich" composition was found to react with the ion conducting Nasicon during thermal treatment, the "sodium-poor" reference mixture was identified as an appropriate reference composition. Screen-printed sensor devices were prepared and tested with respect to CO2 response, reproducibility, and cross-interference of oxygen. Excellent agreement with the theory was observed. With the integration of a screen-printed heater, sensor elements were operated actively heated in a cold gas stream. |
---|---|
ISSN: | 1424-8220 1424-8220 |
DOI: | 10.3390/s8084774 |