The Effect of Finish Line Design on the Fracture Strength of Zirconia Copings
One of the major concerns about all ceramic crowns is their fracture resistance. The purpose of this study was to evaluate the effect of two marginal designs (shoulder 90°, shoulder 135°) on the fracture resistance of zirconia copings. In this study, 20 brass dies were prepared using milling machine...
Gespeichert in:
Veröffentlicht in: | Journal of dentistry (Shiraz) 2019-12, Vol.20 (4), p.271-275 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | One of the major concerns about all ceramic crowns is their fracture resistance.
The purpose of this
study was to evaluate the effect of two marginal designs (shoulder 90°, shoulder 135°) on the fracture resistance of zirconia copings.
In this
study, 20 brass dies were prepared using milling machine: 10 with 1mm width shoulder 90° marginal design and the other 10 with 1mm width shoulder 135° finish line design. Zirconia cores with 0.5mm thickness and 30μm cement space were fabricated on brass dies. The copings were cemented on the dies and fracture test was done using a universal testing machine. Data were analyzed using Mann-Whitney test.
The mean value of fracture resistance for shoulder 90° finish line design were 368.3±109.4 N and for shoulder 135° finish line design were 518.4±115.5 N. Data analysis revealed a statistically significant difference between groups (
< 0.05).
The results of this study showed that the finish line design of zirconia copings influences their fracture resistance. A 135° shoulder finish line design can improve the fracture resistance of zirconia crowns. |
---|---|
ISSN: | 2345-6485 2345-6418 |
DOI: | 10.30476/DENTJODS.2019.77720. |