WEIR COEFFICIENT FOR CYLINDRICAL WEIRS
In this study, the weir coefficient for cylindrical weirs was experimentally investigated. Experiments were conducted for both free and submerged overflow conditions. Experimental results have indicated that the weir coefficient is about 3.50-3.80 for the free overflow condition. The weir coefficien...
Gespeichert in:
Veröffentlicht in: | Mühendislik bilimleri dergisi 2002-01, Vol.8 (1), p.85-90 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this study, the weir coefficient for cylindrical weirs was experimentally investigated. Experiments were conducted for both free and submerged overflow conditions. Experimental results have indicated that the weir coefficient is about 3.50-3.80 for the free overflow condition. The weir coefficient for the submerged overflow condition varies with the amount of submergence. |
---|---|
ISSN: | 1300-7009 2147-5881 |