Performance evaluation of two types of heated cables for distributed temperature sensing-based measurement of soil moisture content
Distributed temperature sensing (DTS) using heated cables has been recently developed for distributed monitoring of in-situ soil moisture content. In this method, the thermal and electrical properties of heated cables have a significant influence on the measurement accuracy of soil moisture content....
Gespeichert in:
Veröffentlicht in: | Journal of Rock Mechanics and Geotechnical Engineering 2016-04, Vol.8 (2), p.212-217 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Distributed temperature sensing (DTS) using heated cables has been recently developed for distributed monitoring of in-situ soil moisture content. In this method, the thermal and electrical properties of heated cables have a significant influence on the measurement accuracy of soil moisture content. In this paper, the performances of two heated cables, i.e. the carbon-fiber heated cable (CFHC) and the metal-net heated cable (MNHC), are studied in the laboratory. Their structures, uniformity in the axial direction, measurement accuracy and suitability are evaluated. The test results indicate that the MNHC has a better uniformity in the axial direction than CFHC. Both CFHC and MNHC have high measurement accuracy. The CFHC is more suitable for short-distance measurement (≤500 m), while the MNHC can be used for long-distance measurement (>500 m). |
---|---|
ISSN: | 1674-7755 |
DOI: | 10.1016/j.jrmge.2015.09.005 |