Theoretical analysis and numerical study of natural convection inside combined solar chimney

Solar chimneys may induce natural ventilation through solar radiation. However, sufficient theoretical studies are needed as a basis to fully exploit passive design in practical green building design. In this work, we investigate the heat transfer properties of turbulent natural convective flows in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy science & engineering 2024-05, Vol.12 (5), p.2052-2071
Hauptverfasser: Cui, Huimin, Han, Mengjiao, Zhang, Jitao, Han, Zhiming, Xu, Feng, Liu, Qingkuan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Solar chimneys may induce natural ventilation through solar radiation. However, sufficient theoretical studies are needed as a basis to fully exploit passive design in practical green building design. In this work, we investigate the heat transfer properties of turbulent natural convective flows in a combined solar chimney with a thermal flux at the absorption wall by means of theoretical analysis and numerical simulations. Two different flow patterns have been found, one with a clear thermal boundary layer flow pattern and the other without, based on high Rayleigh numbers. For flow development in these two flow regimes, the transient scaling analysis is performed separately and the control mechanism for each phase is presented. Some new scale relationships are established to characterize the ventilation performance of solar chimneys, including thermal boundary layer thickness δT, velocity vT, mass flow m, and so on. For the distinct thermal boundary layers, δT,s ~ HΓ2/5/Bo1/5κ2/5, vT,s ~ Bo2/5κ4/5Γ1/5/H, m ~ ρBo1/5κ2/5Γ3/5. For nonobvious thermal boundary layers, vT,f ~ Bo1/3κ/H2/3W1/3, m ~ ρBo1/3κ/A2/3. The important scale relationships are validated using corresponding numerical simulation data, such as the mass flow rate scale M ~ (Γ/κ)3/5Bo1/5 in the distinct thermal boundary layer flow state, and so on. The air changes per hour and heat exchange efficiencies are calculated for a solar chimney with a fixed height‐to‐width ratio to provide a basis for the design of a solar chimney. Theoretical analysis and numerical study of natural convection inside combined solar chimney.
ISSN:2050-0505