Estimation of the glomerular filtration rate in people older than 85: Comparisons between CKD-EPI, MDRD-IDMS and BIS1 equations
Background: The evidence of glomerular filtration rate (GFR) estimating with serum creatinine based formulae in the elderly population is scarce. The purpose of this study is to compare CKD-EPI, MRD4-IDMS and BIS1 equations to analyze correlation and concordance in a population older than 85 years o...
Gespeichert in:
Veröffentlicht in: | Nefrología 2017-03, Vol.37 (2), p.172-180 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background: The evidence of glomerular filtration rate (GFR) estimating with serum creatinine based formulae in the elderly population is scarce. The purpose of this study is to compare CKD-EPI, MRD4-IDMS and BIS1 equations to analyze correlation and concordance in a population older than 85 years old. Patients and methods: We designed a retrospective cross-sectional study, which included data from 600 patients older than 85 years. GFR was estimated by the following equations: CKD-EPI, MDR4-IDMS and BIS1, using as variables sex, age and serum creatinine concentration. Statistics analysis included Wilcoxon test, Bland–Altman plot, non-parametric Passing–Bablok method and kappa statistic (simple and weighted). Results: The patients’ median (range) age was 87 (interval 85–98). The median GFR (range) was 42.4 (5.2–127.4) mL/min/1.73 m2, when it was estimated with MDRD-IDMS, 40.0 (4.5–93.1) for CKD-EPI and 36.9 (7.6–83.7) for BIS1. The comparison of BIS1 and CKD-EPI and MDRD-IDMS using the Wilcoxon test was significant (p |
---|---|
ISSN: | 2013-2514 |
DOI: | 10.1016/j.nefroe.2017.04.011 |