Kinematically Aligned Total Knee Arthroplasty Using Medial Pivot Knee Prosthesis Enhances Medial Pivot Motion: A Comparative Kinematic Study With Mechanically Aligned Total Knee Arthroplasty
Clinical outcomes of kinematically aligned total knee arthroplasty (KA-TKA) have been reported as comparable or superior to those of mechanically aligned TKA (MA-TKA). However, cruciate-retaining prostheses have mostly been used for KA-TKA. This study used medial pivot knee prostheses for KA-TKA, an...
Gespeichert in:
Veröffentlicht in: | Arthroplasty today 2022-02, Vol.13, p.24-28 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Clinical outcomes of kinematically aligned total knee arthroplasty (KA-TKA) have been reported as comparable or superior to those of mechanically aligned TKA (MA-TKA). However, cruciate-retaining prostheses have mostly been used for KA-TKA. This study used medial pivot knee prostheses for KA-TKA, and knee kinematics after KA-TKA were assessed and compared with those after MA-TKA.
Thirteen knees in 9 patients undergoing primary TKA (8 KAs, 5 MAs) were subjected to two-dimensional (2D) to three-dimensional (3D) registration analysis at 1 year postoperatively. Each patient performed weight-bearing activities, and movements were recorded as intermittent digital radiographic images. Three-dimensional implant positions during activities were analyzed for anterior-posterior translation in the sagittal plane, condylar liftoff and mediolateral translation in the coronal plane, and femoral rotation in the axial plane.
Posterior translation of the lateral femoral condyle from 0° to 100° was larger in KA-TKA than in MA-TKA (P = .006). The degrees of condylar liftoff and mediolateral translation were comparable between TKAs. Total external rotation of the femoral component relative to tibial component was significantly greater for KA-TKA (7.7 ± 5.2°) than for MA-TKA (1.3 ± 3.3°; P = .03). The kinematic path of the femoral component revealed greater medial pivoting motion in KA-TKA than in MA-TKA.
KA-TKA using a medial pivot knee prosthesis successfully reproduced the medial pivot pattern and achieved larger femoral external rotation relative to the tibia than MA-TKA. KA-TKA was able to maximize the primary concept of the medial pivot knee prosthesis. |
---|---|
ISSN: | 2352-3441 2352-3441 |
DOI: | 10.1016/j.artd.2021.10.004 |