Myoglobin clearance with continuous veno-venous hemodialysis using high cutoff dialyzer versus continuous veno-venous hemodiafiltration using high-flux dialyzer: a prospective randomized controlled trial
Myoglobin clearance in acute kidney injury requiring renal replacement therapy is important because myoglobin has direct renal toxic effects. Clinical data comparing different modalities of renal replacement therapy addressing myoglobin clearance are limited. This study aimed to compare two renal re...
Gespeichert in:
Veröffentlicht in: | Critical care (London, England) England), 2020-11, Vol.24 (1), p.644-12, Article 644 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Myoglobin clearance in acute kidney injury requiring renal replacement therapy is important because myoglobin has direct renal toxic effects. Clinical data comparing different modalities of renal replacement therapy addressing myoglobin clearance are limited. This study aimed to compare two renal replacement modalities regarding myoglobin clearance.
In this prospective, randomized, single-blinded, single-center trial, 70 critically ill patients requiring renal replacement therapy were randomized 1:1 into an intervention arm using continuous veno-venous hemodialysis with high cutoff dialyzer and a control arm using continuous veno-venous hemodiafiltration postdilution with high-flux dialyzer. Regional citrate anticoagulation was used in both groups to maintain the extracorporeal circuit. The concentrations of myoglobin, urea, creatinine, β2-microglobulin, interleukin-6 and albumin were measured before and after the dialyzer at 1 h, 6 h, 12 h, 24 h and 48 h after initiating continuous renal replacement therapy.
Thirty-three patients were allocated to the control arm (CVVHDF with high-flux dialyzer) and 35 patients to the intervention arm (CVVHD with high cutoff dialyzer). Myoglobin clearance, as a primary endpoint, was significantly better in the intervention arm than in the control arm throughout the whole study period. The clearance values for urea and creatinine were higher in the control arm. There was no measurable albumin clearance in both arms. The clearance data for β
-microglobulin and interleukin-6 were non-inferior in the intervention arm compared to those for the control arm. Dialyzer lifespan was 57.0 [38.0, 72.0] hours in the control arm and 70.0 [56.75, 72.0] hours in the intervention arm (p = 0.029).
Myoglobin clearance using continuous veno-venous hemodialysis with high cutoff dialyzer and regional citrate anticoagulation is better than that with continuous veno-venous hemodiafiltration with regional citrate anticoagulation.
German Clinical Trials Registry (DRKS00012407); date of registration 23/05/2017. https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00012407 . |
---|---|
ISSN: | 1364-8535 1466-609X 1364-8535 1366-609X |
DOI: | 10.1186/s13054-020-03366-8 |