Validation of a grading system for lateral nasal wall insufficiency
This study was designed to validate a grading scheme for lateral nasal wall insufficiency with interrater and intrarater reliability measures. Representative endoscopic videos depicting varied degrees of lateral nasal wall insufficiency were collated into a 30-clip video (15 clips in duplicate). Thi...
Gespeichert in:
Veröffentlicht in: | Allergy & rhinology (Providence, R.I.) R.I.), 2013-01, Vol.4 (2), p.e66-e68 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study was designed to validate a grading scheme for lateral nasal wall insufficiency with interrater and intrarater reliability measures. Representative endoscopic videos depicting varied degrees of lateral nasal wall insufficiency were collated into a 30-clip video (15 clips in duplicate). This was rated by five reviewers for a total of 150 observations. Interrater and intrarater reliability were determined using Fleiss kappa and intraclass correlation coefficient (ICC) statistics, respectively. Good agreement was established between reviewers (interrater reliability), with a Fleiss kappa of 0.7733 (p < 0.01). Analysis of intrarater variability with the ICC revealed a very strong agreement (ICC = 0.88; p < 0.01). The proposed grading system is shown to have good interrater and intrarater reliability. It provides a reliable instrument for assessing lateral wall insufficiency. |
---|---|
ISSN: | 2152-6575 2152-6567 |
DOI: | 10.2500/ar.2013.4.0054 |