DS21, a new noninvasive technology, is effective and safe for screening for prediabetes and diabetes in Chinese population

Screening for prediabetes and asymptomatic diabetes is important for preventing development to an irreversible stage. The current diagnosis of prediabetes and diabetes is based on blood glucose or HbA1c (an invasive method). The aim of this study was to assess the efficacy and safety of DS21, a new...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomedical engineering online 2020-10, Vol.19 (1), p.1-78, Article 78
Hauptverfasser: Zhu, Xiaopeng, Tang, Jing, Lin, Huandong, Chang, Xinxia, Xia, Mingfeng, Wang, Liu, Yan, Hongmei, Bian, Hua, Gao, Xin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Screening for prediabetes and asymptomatic diabetes is important for preventing development to an irreversible stage. The current diagnosis of prediabetes and diabetes is based on blood glucose or HbA1c (an invasive method). The aim of this study was to assess the efficacy and safety of DS21, a new noninvasive technology, for noninvasive screening for prediabetes and diabetes. A total of 939 subjects were divided into a normal control group (NC, n = 308), impaired glucose regulation group (IGR, n = 312), and diabetes (DM) group (n = 319). All subjects underwent the DS21 test, and mean hands-feet, hand, and feet conductance values were analyzed. The diagnostic accuracy of the conductance value was analyzed by receiver-operating characteristic (ROC) curve. The conductance values for hands-feet, hands, and feet in the DM and IGR groups were significantly lower than those in the NC group (all P < 0.01). The area under the ROC curve (AUCROC) for distinguishing NC/IGR was highest when using hands-feet conductance values (0.766 [95% confidence interval, CI 0.730, 0.803]). However, the AUCROCs of distinguishing NC/abnormal glucose metabolism (AGM, including IGR+DM), non-diabetes (NDM)/DM, and IGR/DM were highest when using conductance values for hands at 0.782 [95% CI 0.752, 0.812], 0.688 [95% CI 0.653, 0.723] and 0.573 [95% CI 0.528, 0.617], respectively (all P < 0.01). Hand conductance of values 75.0 (sensitivity 0.769, specificity 0.660), 77.1 (sensitivity 0.718, specificity 0.695), 68.4 (sensitivity 0.726, specificity 0.555), and 58.1 (sensitivity 0.384, specificity 0.744) were recommended as the screening thresholds for NC/AGM, NC/IGR, NDM/DM, and IGR/DM, respectively. A hand conductance value 66.0 was also recommended to distinguish NC/AGM due to its high sensitivity and high PPV. No adverse events occurred in the test. DS21 is fast, noninvasive, low cost, reliable and safe, which makes it a feasible device for screening for prediabetes and diabetes, especially in a large population.
ISSN:1475-925X
1475-925X
DOI:10.1186/s12938-020-00823-x