Measurement of the impuslive force generated by colapsing bubble close to a solid boundary
The article presents experimental results of the acoustical and optical study of cavitation bubble collapse close to a solid boundary in water. The bubble was generated by discharge of low-voltage capacitor into a couple of wires closing a simple circuit. Different distances from the solid wall and...
Gespeichert in:
Veröffentlicht in: | EPJ Web of conferences 2012-01, Vol.25, p.1058 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The article presents experimental results of the acoustical and optical study of cavitation bubble collapse close to a solid boundary in water. The bubble was generated by discharge of low-voltage capacitor into a couple of wires closing a simple circuit. Different distances from the solid wall and different maximum bubble radii were studied. The bubble radius was studied using time-resolved photography and by PVDF film sensor glued on the solid boundary. The illumination was provided by high-power led diode. Synchronization of the system was provided by pulse generator connected to an oscilloscope. The impact power of the bubble to the wall was estimated from the time-resolved photography of the bubble and from the PVDF film sensor signal. The PVDF film sensor calibration was performed by a pendulum test to estimate the impact force. |
---|---|
ISSN: | 2100-014X 2100-014X |
DOI: | 10.1051/epjconf/20122501058 |