Closed reduction of dorsally displaced distal radius fractures in the elderly provided improved final radiographic results

Recent guidelines recommend non-operative treatment as primary treatment in elderly patients with displaced distal radius fractures. Most of these fractures are closely reduced. We aimed to evaluate the radiological results of closed reduction and casting of dorsally displaced distal radius fracture...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of orthopaedic surgery and research 2023-03, Vol.18 (1), p.247-247, Article 247
Hauptverfasser: Hassellund, Sondre Stafsnes, Oftebro, Ingrid, Williksen, John Haakon, Søreide, Endre, Madsen, Jan Erik, Frihagen, Frede
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Recent guidelines recommend non-operative treatment as primary treatment in elderly patients with displaced distal radius fractures. Most of these fractures are closely reduced. We aimed to evaluate the radiological results of closed reduction and casting of dorsally displaced distal radius fractures in patients 65 years or older. A total of 290 patients treated during the years 2015, 2018 and 2019 in an urban outpatient fracture clinic with complete follow-up at least 5 weeks post-reduction were available for analysis. Closed fracture reduction was performed by manual traction under hematoma block. A circular plaster of Paris cast was used. Radiographs pre- and post-reduction and at final follow-up were analyzed. Mean age was 77 years (SD 8) and 258 (89%) were women. Dorsal tilt improved from mean 111° (range 83-139) to 89° (71-116) post-reduction and fell back to mean 98° (range 64-131) at final follow-up. Ulnar variance was 2 mm ((-1)-12) pre-reduction, 0 mm ((-3)-5) post-reduction and ended at mean 2 mm (0-8). Radial inclination went from 17° ((-6)-30) to 23° (SD 7-33), and then back to 18° (0-32) at final follow-up. 41 (14%) patients had worse alignment at final follow-up compared to pre-reduction. 48 (17%) obtained a position similar to the starting point, while 201 (69%) improved. Fractures with the volar cortex aligned after reduction retained 0.4 mm (95% Confidence Interval (CI) 0.1 to 0.7; p = 0,022) more radius length during immobilization. In a regression analysis, less ulnar variance in initial radiographs (OR 1.8 (95% CI 1.4 to 2.3) per mm, p 
ISSN:1749-799X
1749-799X
DOI:10.1186/s13018-023-03733-5