Study of anatomical parameters and intraoperative fluoroscopic techniques for transiliac crest anterograde lag screws fixation of the posterior column of the acetabulum
Background Currently, there is a lack of research investigating the feasibility of employing anterograde lag screw fixation through the iliac crest for minimally invasive percutaneous treatment of the posterior acetabular column, which encompasses retrograde and anterograde screw fixation in posteri...
Gespeichert in:
Veröffentlicht in: | Journal of orthopaedic surgery and research 2023-09, Vol.18 (1), p.1-697, Article 697 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background Currently, there is a lack of research investigating the feasibility of employing anterograde lag screw fixation through the iliac crest for minimally invasive percutaneous treatment of the posterior acetabular column, which encompasses retrograde and anterograde screw fixation in posterior acetabular lag screw fixation. And consequently, the purpose of this study was to examine the anatomical parameters of anterograde lag screw fixation of the posterior column of the pelvis through the iliac crest as well as to investigate the intraoperative fluoroscopy technique, to furnish a scientific rationale supporting the practical utilization of this method within clinical settings. Methods In this study, pelvic CT data of 60 healthy adults, including 30 males and 30 females, were accumulated. The mimics 21.0 software was developed to reconstruct the three-dimensional pelvis model, simulate the anterograde lag screw fixation of the posterior column of the acetabulum through use of the iliac crest, and precisely identify the insertion point: Utilizing the widest iliac tubercle as the starting point, the insertion point was moved toward the anterior superior iliac spine by 1.0 cm at a time until it reached 4.0 cm. With a total of five insertion points, all oriented toward the lesser sciatic notch, the initial diameter of the virtual screw measured 5.0 mm, and it was progressively enlarged by 1.0 mm increments until reaching a final diameter of 8.0 mm. Besides, the longest lengths of virtual screws with distinct diameters at divergent entry points were measured and compared. At the same time, the intraoperative fluoroscopy technique for optimal access was analyzed. Results The cross-section from the iliac crest to the lesser sciatic notch was irregular, with multiple curved shapes. Furthermore, the diameter of the screw was determined by the anteroposterior radians and width of the iliac crest plate, while the screw length was determined by the curvature of the square body. On the condition that the screw diameter of the D channel (3.0 cm outward from the widest part of the iliac tubercle to the lesser sciatic notch) was 5 mm, 6 mm as well as 7 mm, the longest screw lengths were (145.6 [+ or -] 12.8) mm, (143.6 [+ or -] 14.4) mm and (139.9 [+ or -] 16.6) mm, correspondingly, indicating statistically substantial distinctions from other channels (P < 0.0001). Intraoperative fluoroscopy demonstrated that the C-arm machine was tilted (60.7 [+ or -] 2.9) [degre |
---|---|
ISSN: | 1749-799X 1749-799X |
DOI: | 10.1186/s13018-023-04208-3 |