Improvement of Position Estimation of PMSMs Using an Iterative Vector Decoupling Algorithm
This paper presents an improvement of sensorless techniques based on anisotropy for the estimation of the electrical angular position of synchronous machines by means of an iterative algorithm. The presented method reduces the effect of the fourth saliency harmonics on the measured signals avoiding...
Gespeichert in:
Veröffentlicht in: | Energies (Basel) 2021-01, Vol.14 (1), p.245 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper presents an improvement of sensorless techniques based on anisotropy for the estimation of the electrical angular position of synchronous machines by means of an iterative algorithm. The presented method reduces the effect of the fourth saliency harmonics on the measured signals avoiding the use of an observer or filter, thus, no additional dynamics are introduced on the system. Instead, a static algorithm based on iterative steps is proposed, minimizing the angular position error. The algorithm is presented and applied using the DFC (Direct Flux Control) technique but it is not limited to this choice. The advantages and limitations of this method are presented within this paper. The proof of the algorithm convergence is given. Simulations and experimental tests are performed in order to prove the effectiveness of the proposed algorithm. |
---|---|
ISSN: | 1996-1073 1996-1073 |