Computer Guided Implantology Accuracy and Complications
The computer-based method allows the computerized planning of a surgical implantology procedure, using computed tomography (CT) of the maxillary bones and prosthesis. This procedure, however, is not error-free, unless the operator has been well trained and strictly follows the protocol. A 70-year-ol...
Gespeichert in:
Veröffentlicht in: | Case reports in dentistry 2013-01, Vol.2013 (2013), p.1-6 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The computer-based method allows the computerized planning of a surgical implantology procedure, using computed tomography (CT) of the maxillary bones and prosthesis. This procedure, however, is not error-free, unless the operator has been well trained and strictly follows the protocol. A 70-year-old woman whom was edentulous asked for a lower jaw implant-supported prosthesis. A computer-guided surgery was planned with an immediate loading according to the NobelGuide technique. However, prior to surgery, new dentures were constructed to adjust the vertical dimension. An interim screwed metal-resin prosthesis was delivered just after the surgery; however, after only two weeks, it was removed because of a complication. Finally, a screwed implant bridge was delivered. The computer guided surgery is a useful procedure when based on an accurate 3D CT-based image data and an implant planning software which minimizes errors. |
---|---|
ISSN: | 2090-6447 2090-6455 |
DOI: | 10.1155/2013/701421 |