Effect of prone positioning on oxygenation and static respiratory system compliance in COVID-19 ARDS vs. non-COVID ARDS

Background Prone positioning is recommended for patients with moderate-to-severe acute respiratory distress syndrome (ARDS) receiving mechanical ventilation. While the debate continues as to whether COVID-19 ARDS is clinically different from non-COVID ARDS, there is little data on whether the physio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Respiratory research 2021-08, Vol.22 (1), p.1-220, Article 220
Hauptverfasser: Park, Jimyung, Lee, Hong Yeul, Lee, Jinwoo, Lee, Sang-Min
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Prone positioning is recommended for patients with moderate-to-severe acute respiratory distress syndrome (ARDS) receiving mechanical ventilation. While the debate continues as to whether COVID-19 ARDS is clinically different from non-COVID ARDS, there is little data on whether the physiological effects of prone positioning differ between the two conditions. We aimed to compare the physiological effect of prone positioning between patients with COVID-19 ARDS and those with non-COVID ARDS. Methods We retrospectively compared 23 patients with COVID-19 ARDS and 145 patients with non-COVID ARDS treated using prone positioning while on mechanical ventilation. Changes in PaO.sub.2/FiO.sub.2 ratio and static respiratory system compliance (Crs) after the first session of prone positioning were compared between the two groups: first, using all patients with non-COVID ARDS, and second, using subgroups of patients with non-COVID ARDS matched 1:1 with patients with COVID-19 ARDS for baseline PaO.sub.2/FiO.sub.2 ratio and static Crs. We also evaluated whether the response to the first prone positioning session was associated with the clinical outcome. Results When compared with the entire group of patients with non-COVID ARDS, patients with COVID-19 ARDS showed more pronounced improvement in PaO.sub.2/FiO.sub.2 ratio [adjusted difference 39.3 (95% CI 5.2-73.5) mmHg] and static Crs [adjusted difference 3.4 (95% CI 1.1-5.6) mL/cmH.sub.2O]. However, these between-group differences were not significant when the matched samples (either PaO.sub.2/FiO.sub.2-matched or compliance-matched) were analyzed. Patients who successfully discontinued mechanical ventilation showed more remarkable improvement in PaO.sub.2/FiO.sub.2 ratio [median 112 (IQR 85-144) vs. 35 (IQR 6-52) mmHg, P = 0.003] and static compliance [median 5.7 (IQR 3.3-7.7) vs. - 1.0 (IQR - 3.7-3.0) mL/cmH.sub.2O, P = 0.006] after prone positioning compared with patients who did not. The association between oxygenation and Crs responses to prone positioning and clinical outcome was also evident in the adjusted competing risk regression. Conclusions In patients with COVID-19 ARDS, prone positioning was as effective in improving respiratory physiology as in patients with non-COVID ARDS. Thus, it should be actively considered as a therapeutic option. The physiological response to the first session of prone positioning was predictive of the clinical outcome of patients with COVID-19 ARDS. Keywords: COVID-19, Ac
ISSN:1465-993X
1465-9921
1465-993X
1465-9921
DOI:10.1186/s12931-021-01819-4