GuttaFlow ® Bioseal Cytotoxicity Assessment: In Vitro Study
The sealers used for root canal treatment should be biocompatible for the peri-radicular tissues, to evaluate the cytotoxic effects of GuttaFlow bioseal sealer and to compare them with AH26 epoxy resin. Culture media were conditioned with the GuttaFlow bioseal and AH26 pellets. MDPC-23 odontoblast c...
Gespeichert in:
Veröffentlicht in: | Molecules (Basel, Switzerland) Switzerland), 2020-09, Vol.25 (18), p.4297 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The sealers used for root canal treatment should be biocompatible for the peri-radicular tissues, to evaluate the cytotoxic effects of GuttaFlow
bioseal sealer and to compare them with AH26
epoxy resin. Culture media were conditioned with the GuttaFlow
bioseal and AH26
pellets. MDPC-23 odontoblast cell cultures were treated with conditioned medium and serial dilutions. To evaluate the metabolic activity and cellular viability, the MTT and SRB assays were performed. To determine the production of reactive oxygen species, the DHE and DCF-DA probes were used. Cell cycle and cell-death types were assessed by cytometry, and to evaluate the mineralization capacity, the Alizarin Red S coloration was used. Statistical analysis was performed using analysis of variance (ANOVA) when normality was found and Kruskal-Wallis on the opposite case. For the comparison with normality values, the Student
-test was used. Cells exposed to the GuttaFlow
bioseal conditioned medium maintained high metabolic activities, except at higher concentrations. Likewise, viability was maintained, but a significant decrease was observed after exposure to the highest concentration (
< 0.001), associated with cell death by late apoptosis and necrosis. When cell cultures were exposed to AH26
, metabolic activity was highly compromised, resulting in cell death. An imbalance in the production of peroxides and superoxide anion was observed. GuttaFlow
bioseal showed higher biocompatibility than AH26
. |
---|---|