Near-Surface Dose Correlates With Moist Desquamation and Unplanned Reconstructive Surgery in Patients With Implant-Based Reconstruction Receiving Postmastectomy Radiation Therapy
Postmastectomy radiation therapy (PMRT) reduces disease recurrence in appropriately selected patients but may compromise implant-based reconstruction. We investigated whether near-surface dose correlates with radiation-related toxic effects in these patients. Patients receiving PMRT at a single inst...
Gespeichert in:
Veröffentlicht in: | Advances in radiation oncology 2023-11, Vol.8 (6), p.101283-101283, Article 101283 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Postmastectomy radiation therapy (PMRT) reduces disease recurrence in appropriately selected patients but may compromise implant-based reconstruction. We investigated whether near-surface dose correlates with radiation-related toxic effects in these patients.
Patients receiving PMRT at a single institution from 2016 to 2019 were retrospectively reviewed. Patient demographics and treatment information were collected. Three near-surface structures were retrospectively generated, bound by the chest wall tangent beam as well as the skin surface and the skin-3 mm contour (SR3), skin surface and skin-5 mm contour (SR5), or skin-5 and skin-10 mm contours. Dosimetric analysis of these near-surface contours was performed in 2 Gy intervals. Univariate and multivariate analyses were used to identify predictors of moist desquamation, grade 2+ chest wall pain, use of opiate pain medication, unplanned reconstructive surgery, and implant failure. Logistic regression for each outcome and near-surface contour was performed for receiver-operator area under the curve (AUC) analysis and the Youden J Statistic was used to determine the optimal threshold for each dosimetric parameter.
Of 126 patients reviewed, 109 met the study's eligibility criteria. Median follow-up was 2.3 years. Twenty-five patients (23%) underwent unplanned reconstructive surgery, and 10 (9.2%) experienced implant failure. Among clinical variables, low body mass index and history of smoking predicted unplanned surgery on univariate and multivariate analyses, and moist desquamation predicted grade 2+ chest wall pain. The top dosimetric parameters by AUC for moist desquamation, grade 2+ chest wall pain, use of opiates, unplanned reconstructive surgery, and implant failure were SR5 D10 cc (AUC = 0.701, optimal threshold 57.8 Gy, P < .001), SR3 D10 cc (AUC = 0.600, optimal threshold 56.8 Gy, P = .079), SR5 D10 cc (AUC = 0.642, optimal threshold 57.3 Gy, P = .041), SR3 V44 Gy (AUC = 0.711, optimal threshold 81%, P = .001), and SR3 V44 Gy (AUC = 0.688, optimal threshold 82%, P = .052), respectively.
Near-surface dose correlates with moist desquamation and unplanned reconstructive surgery after PMRT. Further evaluation of prospective optimization of dosimetric parameters related to SR3 and SR5 should be considered. |
---|---|
ISSN: | 2452-1094 2452-1094 |
DOI: | 10.1016/j.adro.2023.101283 |