The influence of iris -ciliary angle (ICA) on the vault after implantation of V4c implantable collamer lens: a chain mediation model of ICL haptic related factors

Background This study aims to identify the relationship between iris -ciliary angle (ICA) and the vault. Additionally, we also seek to investigate the chain mediating effects of the ICL haptic related factors on this relationship. Methods The participants were categorized into three groups according...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BMC ophthalmology 2023-10, Vol.23 (1), p.1-403, Article 403
Hauptverfasser: Tan, Weina, Wang, Zheng, Zeng, Qingyan, Lei, Xiaohua, Pan, Chao, Shu, Bao, Jin, Lina, Chen, Qian
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background This study aims to identify the relationship between iris -ciliary angle (ICA) and the vault. Additionally, we also seek to investigate the chain mediating effects of the ICL haptic related factors on this relationship. Methods The participants were categorized into three groups according to the ICA value as follows: low ICA group (< 35[degrees]); moderate ICA group (35[degrees]-70[degrees]); high ICA group (> 70[degrees]). We compared the preoperative ocular characteristics and postoperative examinations among the three groups. Multiple variable stepwise regression was performed to establish the vault prediction formula. The Process V4.0 in SPSS and Hayes's PROCESS model 6 was conducted to further elucidate the mediating effects of the final tip point of ICL haptic and the ICL arc-lens arc on the relationship between the ICA and vault. Results There was a significant difference in the positions of the ICL haptic among three ICA groups. The regression vault equation was Vault = 679.42-7.26*TCA + 192.30*ACD-196.37*CLR + 73.21* STS(horizontal).A significant negative correlation was found between the ICA and vault (P < 0.01).The chain mediation model revealed that the final tip point of ICL haptic and the ICL arc-Lens arc were sequential mediators between ICA and vault (effect = -1.63, 95% CI = -2.72--0.73). Conclusion The ICA was associated with vault via the mediation effect of the final tip point of the ICL haptic and the ICL arc -lens arc. Assessment of ICL haptic related parameters adds significant information to interpret the vault after surgery. Keywords: Iris -ciliary angle, Implantable collamer lens, Haptic, Ultrasound biomicroscopy, Vault
ISSN:1471-2415
1471-2415
DOI:10.1186/s12886-023-03122-w