SPECT-CT Assessment of Pseudarthrosis after Spinal Fusion : Diagnostic Pitfall due to a Broken Screw

A 43-year-old drug addicted female was referred for a L5-S1 posterolateral in situ fixation with autologous graft because of an L5/S1 severe discopathy with listhesis. After six months, low back pain recurred. A Tc-99m HDP SPECT-CT diagnosed a pseudarthrosis with intense uptake of the L5-S1 endplate...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Case reports in orthopedics 2013-01, Vol.2013 (2013), p.1-3
Hauptverfasser: Rager, Olivier, Amzalag, Gaël, Varoquaux, Arthur, Schaller, Karl, Ratib, Osman, Tessitore, Enrico
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A 43-year-old drug addicted female was referred for a L5-S1 posterolateral in situ fixation with autologous graft because of an L5/S1 severe discopathy with listhesis. After six months, low back pain recurred. A Tc-99m HDP SPECT-CT diagnosed a pseudarthrosis with intense uptake of the L5-S1 endplates and a fracture of the right S1 screw just outside the metal-bone interface without any uptake or bone resorption around the screw. The absence of uptake around a broken screw is a pitfall that the physician should be aware of.