Assessment of left ventricular systolic function after VSD transcatheter device closure using speckle tracking echocardiography
Background This is a case-control study conducted on 30 children, 15 with VSD who performed VSD transcatheter device closure (group A) and 15 controls of matching age and gender (group B), in the period between September 2015 and February 2018. We aimed to assess the global left ventricular (LV) sys...
Gespeichert in:
Veröffentlicht in: | The Egyptian heart journal 2019-08, Vol.71 (1), p.1-9, Article 1 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
This is a case-control study conducted on 30 children, 15 with VSD who performed VSD transcatheter device closure (group A) and 15 controls of matching age and gender (group B), in the period between September 2015 and February 2018. We aimed to assess the global left ventricular (LV) systolic function by 2D speckle tracking before and after ventricular septal defect (VSD) transcatheter closure, in comparison to normal controls. All patients were subjected to full history taking; general and cardiac examination; ECG; CXR; full transthoracic echocardiographic examination, including VSD number, size, and site; LV dimensions and volumes; estimated pulmonary artery pressure; right ventricular size and function; left ventricular circumferential; and radial strain imaging by 2D speckle tracking. Patients who had ventricular septal defect closed were reassessed by transthoracic echocardiography after 3 months.
Results
The study included 15 children with VSD: 3 males and 12 females; their age ranged from 2 to 13 years; all had subaortic VSD except for 1 who had apical muscular VSD: VSD size ranged from 3 to 8 mm; PFM coil was used to close defect in all patients except for 2 patients who had an Amplatzer duct occlude I (ADOI) device, and 1 patient needed an additional vascular plug after significant hemolysis. Pre-procedurally, group A had a significantly higher LVEDD, LVESD, and LVEDV than group B. Mean circumferential strain was significantly higher (more negative) in group A than that in group B either pre- or post-procedure. Post-procedurally, there was a significant decrease in circumferential strain (less negative) and a significant increase in radial strain (more positive).
Conclusion
Following transcatheter VSD closure, there is a significant decrease in LV circumferential strain and a significant increase in LV radial strain, which conclude a decrease in LV volume overload with the improvement of its contractility. |
---|---|
ISSN: | 2090-911X 1110-2608 2090-911X |
DOI: | 10.1186/s43044-019-0001-7 |