Characterization and correction of stray light in TROPOMI-SWIR
The shortwave infrared (SWIR) spectrometer module of the Tropospheric Monitoring Instrument (TROPOMI), on board the ESA Copernicus Sentinel-5 Precursor satellite, is used to measure atmospheric CO and methane columns. For this purpose, calibrated radiance measurements are needed that are minimally c...
Gespeichert in:
Veröffentlicht in: | Atmospheric measurement techniques 2018-07, Vol.11 (7), p.4493-4507 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The shortwave infrared (SWIR) spectrometer module of the Tropospheric
Monitoring Instrument (TROPOMI), on board the ESA Copernicus Sentinel-5
Precursor satellite, is used to measure atmospheric CO and methane columns.
For this purpose, calibrated radiance measurements are needed that are
minimally contaminated by instrumental stray light. Therefore, a method has
been developed and applied in an on-ground calibration campaign to
characterize stray light in detail using a monochromatic quasi-point light
source. The dynamic range of the signal was extended to more than 7 orders of magnitude by performing measurements with different exposure times,
saturating detector pixels at the longer exposure times. Analysis of the
stray light indicates about 4.4 % of the detected light is correctable stray
light. An algorithm was then devised and implemented in the operational data
processor to correct in-flight SWIR observations in near-real time, based on
Van Cittert deconvolution. The stray light is approximated by a far-field
kernel independent of position and wavelength and an additional kernel
representing the main reflection. Applying this correction significantly
reduces the stray-light signal, for example in a simulated dark forest scene
close to bright clouds by a factor of about 10. Simulations indicate that
this reduces the stray-light error sufficiently for accurate gas-column
retrievals. In addition, the instrument contains five SWIR diode lasers that
enable long-term, in-flight monitoring of the stray-light distribution. |
---|---|
ISSN: | 1867-8548 1867-1381 1867-8548 |
DOI: | 10.5194/amt-11-4493-2018 |