Although there have been many attempts to increase the therapeutic ratio of radiotherapy for gastric mucosa-associated lymphoid tissue lymphoma (MALToma), only a few planning studies have reported the efficacy of the modern radiotherapy technique till date. Therefore, we performed the dosimetric com...
Gespeichert in:
Veröffentlicht in: | Radiation oncology (London, England) England), 2019-04, Vol.14 (1), p.59-59, Article 59 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Although there have been many attempts to increase the therapeutic ratio of radiotherapy for gastric mucosa-associated lymphoid tissue lymphoma (MALToma), only a few planning studies have reported the efficacy of the modern radiotherapy technique till date. Therefore, we performed the dosimetric comparison among 3-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) plans, using deep-inspiration breath hold (DIBH) or free-breathing (FB) techniques, to determine the most optimal plan for gastric MALToma.
We evaluated 9 patients with gastric MALToma for whom 3D-CRT, step-and-shoot IMRT (
IMRT), volumetric-modulated arc therapy (VMAT), and tomotherapy plans with identical prescribed doses were generated using DIBH or FB computed tomography (CT). Planning target volume (PTV) coverage and non-target doses were calculated for each plan and compared with plan quality metric (PQM) scores.
All 72 plans of 9 patients satisfied our dosimetric goals, and the IMRT plans and 3D-CRT plans had similarly good conformity index values with no differences related to respiratory movement. IMRT plans yielded significantly better doses to the organs-at-risk, and DIBH plans yielded significantly lower liver, heart, and lung D
and spinal cord D
with smaller irradiated volumes compared to FB plans. For the mean PQM scores, VMAT-DIBH and
IMRT-DIBH yielded the best scores, whereas 3D plans provided reduced beam monitor unit values.
Our findings demonstrate that modern RT technologies (DIBH with VMAT or
IMRT) could potentially provide excellent target coverage for gastric MALToma while reducing doses to organs-at-risk. However, the relevance of the most optimal plan considering clinical outcomes should be confirmed further in a larger patient cohort. |
---|---|